Approx. Rs 1.7 Lakh / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Usage/Application | ONLINE POLLUTION CHECKING MACHINES |
Model Name/Number | AVG-500 |
Voltage | 140-260volts AC(50Hz) ,50 Watts |
Automation Grade | Automatic |
Material | Iron |
Display Type | 128 Dots X 64Dots graphical liquid crystal display |
Power Source | 140-260volts AC(50Hz) ,50 Watts |
I Deal In | New Only |
Brand | AIRVISOR |
Gases Measured |
Carbon monoxide, Hydro carbons (Hexane), Carbon dioxide, Oxygen and Nox. |
Measurement Principal |
NDIR sensor for CO,HC & Co2 ,/Electrochemical sensor for O2 Nox. |
Measurement span |
CO: 0-15% Vol. HC: 0-15000 ppm(Hexane)Co2 : 0-20% vol. O2 :0-25% vol. Nox: 0-1000ppm(optional in case of 5 gas analyser) |
Lambda |
0.500-9.500 |
AFR |
8.00-27.00 |
RPM(Optional) |
Inductive: 0-6000RPM Battery:0-8000RPM,Magnetic: 0-6000RPM |
Oil temp.(Optional) |
0-150°C |
Channel resolution |
C0:0.001% HC: 1 PPM,CO2 : 0.01% NOX : 1PPM RPM: 10 ?? |
Accuracy |
CO: ± 0.06% HC: ±12PPM CO2: ±0.40% O2 : ±0.10% NOX: ±10PPM RPM: ±10 ?? |
Display |
128 Dots X 64Dots graphical liquid crystal display |
Input method |
6 keys membrane keyboard(inbuilt in front panel) |
Warm up time |
≤ 5 Minutes |
Auto Zeroing |
≤ 15sec. |
Sample flow rate |
3L/Minute with auto drain facility |
Pump type |
Dual head piston diaphragm pump |
Printer(Optional) |
Thermal printer |
Dimensions |
(L)280mm X (w) 250mm X (H)140mm |
Weight |
6Kgs |
Operating temp. |
-5°C to 55°C |
Power requirement |
140-260volts AC(50Hz) ,50 Watts |
Standard Accessories |
Gas analyzer unit, power cord, communication cable, sampling probe, sampling pipe,leake test cap,OEM pc software, user manual |
Additional Information:
Approx. Rs 6 Lakh / UnitGet Latest Price
Product Details:Model | AutoHex II Scan Tool |
Brand | Autohex |
Language Type | English |
Type | Key Programmer |
Package Size | 3.0 * 19.0 * 7.0 (cm) |
Gross Weight | 0.6 ( kg ) |
Additional Information:
Approx. Rs 24,500 / PieceGet Latest Price
Product Details:Capacity | 4000 lbs |
Product Code | T32002 |
Lifting range | 1"-78.75" |
Net weight | 203.7 lbs |
Gross weight | 215.9 lbs |
Package size | 59.8"x21.3"x6.3" |
Additional Information:
Approx. Rs 15,000 / PieceGet Latest Price
Product BrochureProduct Details:Minimum Order Quantity | 1 Piece |
Brand | G-AUTO PROBE |
Display | Digital |
Usage/Application | For sensor test,relay test and actuator test |
Additional Information:
Approx. Rs 1.85 Lakh / BoxGet Latest Price
Product Details:Minimum Order Quantity | 1 Box |
Model | AVS500 |
Application | Laboratory Use |
Display (Inch) | 128 X 64 Dots (Graphical LCD) |
Response Time | Less than equal 15 sec |
Weight (Kilogram) | 7kg |
Humidity (%) | 0 to 90% (Non-Condensing) |
Source Voltage 90 (Volt) | 110 to 220 Volts AC |
Communication Function | RS232 (Serial) for PC Connection |
Operating Temp Deg Celsius | 0 to 50 Degree Celcius |
Overview of Product:
The AVG-500, 5 Gas Analyzer developed by AIRVISOR TECHNOLOGIES is best product in it’s class. Due to its latest technology and spares used for its development, it becomes a product which never been introduced in Indian market. Dual Head pump provides faster response time for gas sampling. While automatic drain facility ensures the vapor separation from the exhaust sample. Multi display pages offers user to switch between pre-configured measurement items on each page, it offers user to select either big font size display page or all gases in a single page, another page provided to have a look on Oil Temp, Corrected CO, AFR, PEF, RPM. AVG-500 is designed using “CAP3030 NDIR Gas Bench” manufactured by CAPELEC-France.
Scope:
The AVG-500 is intended to use for measurement of emission gases i.e. Carbon Monoxide, Carbon Dioxide, Hydro-Carbons, Oxygen through tail pipe of internal combustion engines running on fossil fuels like Petrol / CNG / LPG. Proper filtration of exhaust sample is recommended during measurements.
Usage Condition:
The AVG-500 is designed to use within range of 160 volts to 250 volts AC at 50/60 Hz frequency. Using beyond these specifications may cause serious damage of power supply unit. To ensure prevention of electrical shocks, proper earth in power supply is required. The equipment is designed for indoor and outdoor usage keeping in mind that equipment should be used in a well ventilated and shaded place. Use of the equipment in rainy and misty conditions will require regular inspection of water separator unit to ensure proper drain of condensation. Due to sensitive parts used in this equipment, it is required to operate by a trained operator only. The equipment should be strictly opened / serviced by a qualified service engineer because it contains corrosive materials which may lead to serious injuries. The equipment must not be used with soiled or damaged filters which may cause dust contamination in sample line and lead to major break downs. Periodic maintenance of the equipment should be carried out in timely manners as specified in General Maintenance section.
Additional Information:
Approx. Rs 2,500 / PieceGet Latest Price
Product Details:Item Code | T42002A |
Capacity | 2 Ton |
Lifting Range | 10.9"-16.5" |
Net Weight | 11 lbs |
Gross Weight | 12.13 lbs |
Packaging Size | 7.68"x7.09"x13.78" |
Explore More Products
© MBL Impex Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited